Slider

Vessel Information

Print Q88

KEJORA ONE
BARGE
2,678
1,998
4.687
14.60
UNSUITABLE (SENOKO - SEE REMARKS)
NO SIRE/TERMINAL INSPECTION REPORT
9083378
1995
2.00
32.00
3.232
78.60
5.232

SERAYA POWER STATION (FO OPS)
Vessel is suitable for Jetty 3 only.
Her LOA of 78.60m is below Jetty 1 & 2 minimum LOA requirement of 110m & 95m respectively.
Her Ballast PBL of 32.00m is below the minimum Ballast PBL requirement of 45m for Jetty 1A/B, 2A/B & 4.

 

SENOKO POWER STATION
Vessel is not suitable for Senoko jetty as her parallel body length of 32.0m at ballast condition is below the minimum acceptable parallel body length of 45m.

AESIR TRADING PTE LTD

05/05/20: EVALUATION (PS FOR GO OPS), RATING: UNSUITABLE, REASON: NO SIRE/TERMINAL INSPECTION REPORT

04/05/20: EVALUATION (SP), RATING: UNSUITABLE, REASON: INSUFFICIENT BALLAST PBL

NAME CHANGE: NITSA TO KEJORA ONE (06/04/20)

30/05/19: TO BE NOMINATED

01/06/18: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (31/05/18)

31/08/18: TERMINAL INSPECTION (OTS)

16/08/17: EVALUATION (PS FOR FO OPS), RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (26/07/17)

26/08/16: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (25/08/16)

25/08/16: TERMINAL INSPECTION (OTS)

29/07/16: EVALUATION, RATING: UNSUITABLE, REASON: NO SIRE/TERMINAL INSPECTION REPORT

15/04/16: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (28/08/15)

07/09/15: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (28/08/15)

08/06/15: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (11/10/14)

11/10/14: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (11/10/14)

11/10/14: TERMINAL INSPECTION (OTS)

01/10/14: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (29/11/13)

11/08/14: EVALUATION, RATING: UNSUITABLE, REASON: NO SIRE/TERMINAL INSPECTION REPORT

17/09/13: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (06/09/12)

16/09/13: EVALUATION, RATING: UNSUITABLE, REASON: NO SIRE/TERMINAL INSPECTION REPORT

10/06/13: EVALUATION, RATING: UNSUITABLE, REASON: NO SIRE/TERMINAL INSPECTION REPORT

09/10/12: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (29/06/12)

10/04/12: EVALUATION, RATING: UNSUITABLE, REASON: NO SIRE/TERMINAL INSPECTION REPORT

17/05/11: EVALUATION, RATING: ELIGIBLE, REASON: SIRE REPORT (26/04/11)

28/10/10: EVALUATION, RATING: ELIGIBLE, REASON: SIRE REPORT (18/09/10)

14/04/10: EVALUATION, RATING: ELIGIBLE, REASON: SIRE REPORT (18/03/10)

13/06/09: EVALUATION, RATING: ELIGIBLE, REASON: SIRE REPORT (20/05/09)

26/03/09: EVALUATION, RATING: ELIGIBLE, REASON: SIRE REPORT (14/06/08)

15/12/08: EVALUATION, RATING: ELIGIBLE, REASON: SIRE REPORT (14/06/08)

06/05/08: EVALUATION, RATING: ELIGIBLE, REASON: TERMINAL INSPECTION REPORT (23/04/08)

Email: safe-ships@safe-ships.sg